No routine maintenance is necessary apart from occasional cleaning.
Both models are splashproof to IPX4 standard.
Electrical
WARNING - This appliance must be earthed
The electrical installation of this towel rail must be carried out by a
competent electrician in accordance with the current I.E.E Regulations
for Electrical Equipment. The towel rail is suitable for use on an A.C.~
electrical supply. Before installation check that the supply voltage
corresponds with that marked on the rail.
IMPORTANT - The wires in the mains lead are coloured in
accordance with the following code:
GREEN/ YELLOW
As the colours of the wires in the mains lead of this
appliance may not correspond with the coloured markings identifying
the terminals in your plug, proceed as follows:
The wire which is coloured GREEN and YELLOW must be
connected to the terminal in the plug which is marked with the letter
E or by the earth symbol
or coloured green or green and yellow.
The wire which is coloured BLUE must be connected to the terminal
which is marked with the letter N or coloured black.
The wire which is coloured BROWN must be connected to the terminal
which is marked with the letter L or coloured red.
This appliance must only be used on A.C. mains supply of 230/240
Installation
If fitted in a room containing a bath or shower, to comply with the
Regulations,
necessary with the supply to the heater controlled by a
double-pole pull-cord switch having a contact separation of 3mm in
each pole. The body of the switch should be situated as to be
normally inaccessible to a person using a bath or shower.
IMPORTANT - Protect the electrical connection whilst
handling the towel rail.
The towel rail must be permanently fixed to the wall using the wall
brackets supplied. The rail must be mounted vertically as shown
observing the minimum clearances stated.
WARNING - The towel rail is heavy. Care must be taken when lifting
and fitting the towel rail.
Wall or ceiling mounted (6 pages)